MCC-IP 交换机上报告了 "DomainMismatchFromNodeToShelf_Alert"
适用于
- ONTAP 9
- MetoCluster-IP
问题描述
MCC-IP 交换机上报告了 "DomainMismatchFromNodeToShelf_Alert":
Node Node4004
Monitor system-connect
Alert ID DomainMismatchFromNodeToShelf_Alert
Alerting Resource Switch-04
Subsystem SAS-connect_Cluster
Indication Time Fri Jul 25 08:52:47 2025
Perceived Severity Major
Probable Cause Configuration_error
Description The storage domain between the nodes Node3004, Node4004 and switch Switch-04 is different from the domain between the switch and shelves 4.40, 4.50, 4.60, 4.70.
Corrective Actions Connect the switch SCLSW4004 to both the node and the shelves with the same storage domain, following the guide applicable to your shelf.
Possible Effect This issue will affect conversions to direct-attached storage.
Additional Information Switch Name: Switch-04
Nodes: Node3004, Node4004
Ports: Node3004:e10a, Node4004:e10a
Connected Shelves: 4.40, 4.50, 4.60, 4.70
Nodes Connected to Switch Port Range A: Switch3004, Switch4004
Nodes Connected to Switch Port Range B:
Alerting Resource Name Switch name: Switch-04