跳转到主内容

CORTP-63621:端口切换活动导致后端iSCSI连接不一致

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

问题描述

  • Temporary loss of connectivity between clusters can result in remote drives being marked as not responding. Event log would report similar messages:
[[NodeA: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:185abf42-1aba-11eb-a6fc-d039ea45ec7d (address: 10.1.2.3). Reason: no ping reply after 5 seconds.] [[NodeA: kernel: iscsi.session.stateChanged:notice]: iSCSI session state is changed to Reconnecting for the target iqn.2016-07.com.netapp:f4d3fb1c-1aba-11eb-a87d-d039ea45eac8 (type: dr_partner, address: 10.1.1.4:65200). Reason: no ping reply after 5 seconds.]
  • sysconfig -a shows an output similar to the below:

[ slot 0: Virtual iSCSI Host Adapter 0m ... 10.20: NETAPP X371_SLNGE960ATE NA52 915.4GB 520B/sect (S/N) (Failed)]

  • sysconfig -r output is similar:
[Local broken disks

RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- not responding 0m.i2.1L21P3 0m 0 21 1 SSD N/A 63849/130764288 63857/130780672

...

not responding 0m.i1.3L27 0m 10 20 1 SSD N/A 915465/1874872832 915715/1875385008 ]

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.