问题描述

  • 集群之间暂时断开连接可能会导致远程驱动器被标记为无响应。事件日志会报告类似消息:

[[neda:INTR:ctl.session.stateChanged:notice]: iSCSI CAM目标层的会话状态对于启动程序iqn.1994-09.org.freebsd:185abf42-1aba-11eb-a6fc-d039ea45ec7d (地址:10.1.2.3)已更改为终止。原因:5秒后无ping应答。]
[[neda:kernel: iscsi.session.stateChanged:notice]: iSCSI session state is changed to Reconnecting for the target iqn.2016-07.com.netapp:f4d3fb1c-1aba-11eb-a87d-d039ea45eac8 (type:dr_Partner、address:10.1.1.4:65200).原因:5秒后无ping应答。]
  • Sysconfig -a显示类似于以下内容的输出:
    [插槽0:虚拟iSCSI主机适配器0m...

    10.20:NetApp X371_SLNGE960ATE NA52 915.4GB 520B/节(S/N)(失败)]

  • Sysconfig -r输出与此类似:

[本地损坏的磁盘
RAID磁盘设备高可用性磁盘架托架槽池类型RPM已用(MB/秒)物理磁盘(MB/秒)-------------------------------

未响应0m.i2.1L21P3 0m 0 21 1 SSD不适用63849/130764288 63857/130780672...

未响应0m.i1.3L27 0m 10 20 1 SSD不适用915465/1874872832 915715/1875385008 ]

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.