跳转到主内容

CONTAP-514944:ONTAP 升级到 9.13.1P17、9.15.1P13、9.15.1P14 或 9.16.1P6 后,MetroCluster DR/NVRAM 脱机。

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

问题描述

在 ONTAP 升级到 9.13.1P17、9.15.1P13、9.15.1P14 或 9.16.1P6 后,使用 T6 适配器的 MetroCluster IP 系统的客户可能会遇到以下错误:
nvmm_error: nvmm.mirror.aborting:debug]: mirror of sysid 2, partner_type DR PARTNER and mirror state NVMM_MIRROR_OFFLINE is aborted because of reason NVMM_ABORT_SYNCING_MIRROR.
nvmm_mirror_sync: nvmm.mirror.aborting:debug]: mirror of sysid 2, partner_type DR PARTNER and mirror state NVMM_MIRROR_OFFLINE is aborted because of reason NVMM_ERR_BAILOUT

  • 这仅影响使用 T6 适配器(X1146A)或板载 T6 适配器的 MetroCluster IP 系统。
  • 对数据可用性没有已知的影响。
  • 此缺陷将阻止 MetroCluster 切换

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.