跳转到主内容

从集群中删除节点后出现SwitchIfDeal_Alert

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
HW
Last Updated:

适用场景

  • ONTAP 9
  • 有交换机集群

问题描述

  • 为非ISL端口显示运行状况警报SwitchIfDead警报:
Node::> system health alert show
Node: Node-01
Alert ID: SwitchIfDead_Alert
Resource: Ethernet1/7
Severity: Major
Indication Time: Tue Mar 25 17:19:34 2025
Suppress: false
Acknowledge: false
Probable Cause: The interface
Cluster-sw2(FOCXXXXXXXX)/Ethernet1/7 is up,
but it is not passing unicast traffic.
Possible Effect: The lack of transmit or receive traffic reported by
the switch can indicate issues with port-level or
switch-level data packet forwarding.
Corrective Actions: 1) Check interface counters and neighbor discovery information to verify the port's activity.
2) Check cluster and switch health status.
  • EMS日志显示以下消息:
[Node-01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchIfDead_Alert , Alerting Resource = Cluster-switch(XXXXXXXXXX)/Ethernet1/7 raised by monitor ethernet-switch
  • 节点最近已从集群中删除、但仍连接到集群交换机。
  • 旧节点使用的交换机端口仍由管理员管理且运行正常。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.