适用场景

  • ONTAP 9
  • 集群网络交换机
  • N9K-C9336C -FX2

问题描述

  • CSHM报告 SwitchPowerNotPresent_AlertSwitchPowerUnknown_Alert 集群网络交换机的和
  • 交换机日志中的PSU状态正常

`show environment`

Fan:
---------------------------------------------------------------------------
Fan        Model         Hw    Direction     Status
---------------------------------------------------------------------------
Fan1(sys_fan1)  NXA-FAN-65CFM-PE    --    back-to-front   Ok
Fan2(sys_fan2)  NXA-FAN-65CFM-PE    --    back-to-front   Ok
Fan3(sys_fan3)  NXA-FAN-65CFM-PE    --    back-to-front   Ok
Fan_in_PS1    --           --    back-to-front   Ok
Fan_in_PS2    --           --    back-to-front   Ok
Fan Zone Speed: Zone 1: 0xb3
Fan Air Filter : NotSupported

Power Supply:
Voltage: 12 Volts
Power            Actual        Actual     Total
Supply   Model       Output        Input     Capacity    Status
              (Watts )       (Watts )    (Watts )
-------  ----------  ---------------  ------  ----------  --------------------
1     NXA-PAC-1100W-PE2    146 W        166 W    1100 W    Ok
2     NXA-PAC-1100W-PE2    166 W        186 W    1100 W    Ok

  • 几分钟后、这些警报会自动清除
示例:
 
Thu May 04 18:41:52 [cluster: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = cluster_switch(xxxxxxxxxxx)/PowerSupply-1 raised by monitor ethernet-switch
Thu May 04 18:42:09 [cluster: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPowerNotPresent_Alert[cluster_switch(xxxxxxxxxxx)/PowerSupply-1].
Thu May 04 18:55:26 [cluster: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerUnknown_Alert , Alerting Resource = cluster_switch(xxxxxxxxxxx)/PowerSupply-1 raised by monitor ethernet-switch
Thu May 04 18:57:09 [cluster: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPowerUnknown_Alert[cluster_switch(xxxxxxxxxxx)/PowerSupply-1].
 
Thu May 04 19:02:28 [cluster: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerNotPresent_Alert , Alerting Resource = cluster_switch(xxxxxxxxxxx)/PowerSupply-1 cleared by monitor ethernet-switch
Thu May 04 19:02:28 [cluster: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerUnknown_Alert , Alerting Resource = cluster_switch(xxxxxxxxxxx)/PowerSupply-1 cleared by monitor ethernet-switch
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.