由于缺少冗余交换机条目,出现 ClusterSwitchConnectionDegraded_Alert
适用于
- ONTAP 9
- 事件消息系统 (EMS)
- 集群交换机
问题
- EMS 报告"ClusterSwitchConnectionDegraded_Alert"
Fri Dec 20 19:11:41 +0100 [CLUSTER-01: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConnectionDegraded_Alert , Alerting Resource = CLUSTER-01 raised by monitor ethernet-switch
- 在系统健康警报中可以看到相同的警报
Cluster::*> system health alert show
Node: node
Alert ID: ClusterSwitchConnectionDegraded_Alert
Resource: node
Severity: Major
Indication Time: Thu Mar 06 15:03:16 2025
Suppress: false
Acknowledge: false
Probable Cause: Only one cluster switch,
"switch", has been discovered
to be connected to the cluster ports of node
"node". If a cluster connection was not
discovered, but the expected cluster switch is listed
in the output of "system switch ethernet show", it
indicates that the node is not currently receiving
discovery information about the missing switches.
- 但是,从设备发现中,我们可以看到这两台交换机
Cluster::> network device-discovery show
Node/ Local DiscoveredProtocol Port Device Interface Platform----------- ------ ------------------------- ---------------- ----------------Cluster-N1/cdp e0a ClusterSW1(XXXXXXX) Ethernet1/10 N9K-C9336C-FX2 e0b ClusterSW2(YYYYYYY) Ethernet1/11 N9K-C9336C-FX2Cluster-N1/cdp e0a ClusterSW1(XXXXXXX) Ethernet1/10 N9K-C9336C-FX2 e0b ClusterSW2(YYYYYYY) Ethernet1/11 N9K-C9336C-FX2
- 从 system switch ethernet show 中,我们只能看到一个交换机的条目
Cluster::*> system switch ethernet show -instance
Device Name: ClusterSW2 IP Address: 192.xx.x.9 SNMP Version: SNMPv2c Is Discovered: true Community String or SNMPv3 Username: cshm1! Model Number: N9K-C9336C-FX2 Switch Network: cluster-network Software Version: Cisco Nexus Operating System (NX-OS) Software, Version 10.3(4a) Reason For Not Monitoring: Monitoring disabled by user Source Of Switch Version: CDP/ISDP Is Monitored ?: false Serial Number of the Device: unknown