报告了运行配置不正确的交换机的ClusterIfIslDownWarn
适用场景
- Cisco Nexus集群交换机
- ONTAP 9
问题描述
- 在应用新RCf后、集群报告ClusterIfIslDownWarn。
Node: NetappNode1
Alert ID: ClusterIfIslDownWarn_Alert
Resource: Ethernet1/32
Severity: Major
Indication Time: Thu Mar 07 08:48:42 2024
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch
"Cluster-sw02(FDXXXXXXY)/Ethernet1/32" to the
ISL port might be faulty. For the port-channel, please
check each individual link.
Possible Effect: Cluster redundancy might be lost.
Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After
reconnecting it, verify whether the link of the ISL
port is up by executing the commands per the switch
configuration guide or by checking whether the Link
status LED is on. 在实际RCF文件和交换机的
show running-confg
命令输出中观察到的差异。