Cisco 9336交换机报告温度传感器过高
适用场景
- 从NetApp购买的Cisco Nexus 9336交换机
- NXOS 10.1 ( 1 )
- NXOS 10.1 ( 2 )
问题描述
- ONTAP在中报告高温警报
system health alert show:
Sensor "module-1 BACK" on switch "SW-A1(XXXXXXXXXX)" is reporting a temperature of 4294967168 C, which is above the critical threshold
- 在
show environment
中,将显示以下内容
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
1 FRONT 80 70 28 Ok
1 BACK 70 42 n/a Failure
1 CPU 90 80 36 Ok
1 Heavenly 110 90 45 Ok
- 可能存在运行状况警报
SwitchTemperatureCritical_Alert
[Node-1: cshmd: hm.alert.raised:alert]: Alert Id = SwitchTemperatureCritical_Alert , Alerting Resource = XXXXXXXXXXXX(XXXXXXXXXXXX)/module-1 BACK raised by monitor ethernet-switch