跳转到主内容

Brocade FC端口脱机且NO_Module状态

Views:
10
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • 所有Brocade硬件平台
  • 所有Brocade网络结构操作系统(FOS)平台

问题描述

  • 连接到终端设备(主机、存储、ATto等)的Brocade光纤通道端口从正常状态切换到No_module  状态

SWITCHCMD /fabos/bin/switchshow:
Index Slot Port Address Media Speed State Proto
============================================================
120 4 24 667800 -- N32 No_Module FC

  • Sfpshow 表示没有为该特定端口安装介质

=============
Slot 4/Port 24:
=============
Media not installed
Extended smart data is Not available

  • 要找到问题描述、可以执行以下故障诊断步骤
    • 检查该特定端口上是否存在任何SFP。
    • 如果存在SFP、请重新拔插该端口上的SFP模块。
    • 如果重新拔插后问题描述仍然存在、请将其更换为已知良好的SFP并验证端口状态。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.