跳转到主内容

反复SwitchPowerFail_Alert,交换机上出现故障警报

Views:
2
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP
  • BES-53248群集交换机

问题描述

  • 有关集群交换机电源故障的重复警告、但在没有干预的情况下清除
[Cluster1-02: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = Clus-SW1/PowerSupply-1 raised by monitor ethernet-switch
[Cluster1-02: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = Clus-SW1/PowerSupply-1 cleared by monitor ethernet-switch


 
[Cluster1-02: cshmd: hm.alert.raised:alert]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = Clus-SW1/PowerSupply-1 raised by monitor ethernet-switch
[Cluster1-02: cshmd: hm.alert.cleared:notice]: Alert Id = SwitchPowerFail_Alert , Alerting Resource = Clus-SW1/PowerSupply-1 cleared by monitor ethernet-switch

 
 
  • 在交换机上运行"show Logging buffed"会显示PSU断电、然后立即清除警报

(Clus-SW1)#show logging buffered

Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137908 %% INFO Unit 1 power supply 2 OPERATIONAL event (3) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137907 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 2  Event: 5 - Power Loss
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137906 %% WARN Unit 1 power supply 2 POWER LOSS event (5) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137905 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 2  Event: 3 - Operational
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137904 %% INFO Unit 1 power supply 2 OPERATIONAL event (3) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137903 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 1  Event: 3 - Operational
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137902 %% INFO Unit 1 power supply 1 OPERATIONAL event (3) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137901 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 2  Event: 5 - Power Loss
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137900 %% WARN Unit 1 power supply 2 POWER LOSS event (5) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137899 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 1  Event: 5 - Power Loss
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137898 %% WARN Unit 1 power supply 1 POWER LOSS event (5) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137897 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 1  Event: 3 - Operational
Clus-SW1 BOXSERV[boxs_Req]: boxs.c(1687) 137896 %% INFO Unit 1 power supply 1 OPERATIONAL event (3) occurred.
Clus-SW1 TRAPMGR[boxs_Req]: traputil.c(826) 137895 %% NOTE Power supply state change alarm: Power Supply Unit: 1  ID: 1  Event: 5 - Power Loss

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.