Brocade G610意外重新启动多次
适用场景
- Brocade G610
问题描述
- Brocade G610意外重新启动多次、没有明显原因
errdump -a
2022/02/08-19:04:19, [HAM-1004], 238, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]2022/02/28-09:36:49, [HAM-1004], 246, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.
[...]
2022/03/23-09:55:31, [HAM-1004], 261, CHASSIS, INFO, BrocadeG610, Processor rebooted - Reset.psshowPower Supply #1 is OKfanshowFan 1 is Ok, speed is 7425 RPMFan 2 is Ok, speed is 7345 RPMFan 3 is Ok, speed is 7425 RPMFan 4 is Ok, speed is 7425 RPMsensorshowsensor 1: (Temperature) is Ok, value is 23 Csensor 2: (Temperature) is Ok, value is 23 Csensor 3: (Temperature) is Ok, value is 26 Csensor 4: (Temperature) is Ok, value is 25 Csensor 5: (Temperature) is Ok, value is 21 Csensor 6: (Temperature) is Ok, value is 19 Csensor 7: (Temperature) is Ok, value is 25 Csensor 8: (Temperature) is Ok, value is 22 Csensor 9: (Temperature) is Ok, value is 37 Csensor 10: (Fan ) is Ok,speed is 7425 RPMsensor 11: (Fan ) is Ok,speed is 7345 RPMsensor 12: (Fan ) is Ok,speed is 7425 RPMsensor 13: (Fan ) is Ok,speed is 7425 RPMsensor 14: (Power Supply) is Ok- 已验证电源线是否正确就位、并验证为交换机供电的组件(插槽、线路、电缆、UPS等)的运行状况。
- 即使 换用了电源线和插座、问题描述仍然存在
- 同一不间断电源(UPS)/电路上的其他组件不受影响。