跳转到主内容

VMware ESXi主机发现E系列阵列的IOPS较低

Views:
4
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg<a>2009966095</a>
Last Updated:

适用场景

  • E系列
  • VMware ESXi

问题描述

VMware ESXi出错:

I/O latency increased from average value of 16649 microseconds to 366839 microseconds""。

故障排除步骤

  • 验证用于创建卷组或磁盘池的驱动器数量。
  • 根据磁盘转数计算OP。
    • 示例:如果磁盘RPM为7200,则每个驱动器最多可支持85-100 IOPS。
    • 公式number of drive in the volume group or disk pool * iops

注意:在计算磁盘池的总IOPS时,需要排除 保留驱动器计数。

基于磁盘rpm的IOPS表

Device    Type  IOPS        Interface
=========== ===== ================ ===========
7,200 rpm   SATA  ~75-100 IOPS[2]  SATA 3 Gb/s
10,000 rpm  SATA  ~125-150 IOPS[2] SATA 3 Gb/s
10,000 rpm  SAS   ~140 IOPS[2]    SAS
15,000 rpm  SAS   ~175-210 IOPS[2] SAS

  • 验证 ISCSI-STATISTICS.CSV 文件中是否报告了任何错误。

  • 检查驱动器端是否有任何打开的和排队的请求。

-> chall 0
 
chAll (Tick 1261153685) ==> 03/07/24-22:59:11
 
2806-A 08.74.01.00
.....Channels.....:...........Target...........:............Initiator..........:               
       Link :ITN :..........IOs..........:ITN :............IOs...........:.........Busy.........Idle.
  Ch H/D STP Down :cnt : Open  Completed  Errs :cnt : Qd  Open Completed  Errs:       Ms       Ms 
---- --- --- ---- :--- :----- ---------- ----- :--- :--- ----- ---------- -----: ------------ -------------
  0 Drv SAS   0 :  1 :   0    42039    0 : 10 :  0   33  63446794    0:    51609897    3232649
  1 Drv SAS   0 :  1 :   0    41952    0 : 10 : 21   45  54312522    0:    51465021    3377524
  2 Hst iSC   0 :  1 :   0   22222954   673 :  0 :  0    0      0    0:    54842546       0
  3 Hst iSC   0 :  1 :   36   22218796   462 :  0 :  0    0      0    0:    54842546       0
  4 Drv iSA   0 :  0 :   0      0    0 :  1 :  0    0     315    0:      489    54842056

  • 验证网络级别是否存在任何数据包丢弃/错误。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.