跳转到主内容

NVMe RDMA 路径在重新启动 E-Series 控制器后保持连接

Views:
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software
Specialty:
esg
Last Updated:

适用于

  • E-Series EF80
  • SANtricity 操作系统 12.10R 或更早版本
  • RoCE (融合以太网上的 RDMA)
  • NVMe over RoCE

问题

  • 一些 NVMe/RDMA 路径在控制器重新启动后保持连接状态,而同一子系统上的其他路径保持活动状态
  • nvme list-subsys 命令将一些 NVMe/RDMA 路径显示为 connecting

示例:

+- nvme6 rdma traddr=<TARGET_ADDRESS>,trsvcid=4420,host_traddr=<HOST_ADDRESS> live
+- nvme7 rdma traddr=<TARGET_ADDRESS>,trsvcid=4420,host_traddr=<HOST_ADDRESS> live
+- nvme8 rdma traddr=<TARGET_ADDRESS>,trsvcid=4420,host_traddr=<HOST_ADDRESS>connecting
+- nvme9 rdma traddr=<TARGET_ADDRESS>,trsvcid=4420,host_traddr=<HOST_ADDRESS> live

  • Linux 主机日志重复显示 I/O 队列创建被拒绝的消息:

示例:

nvme nvme8: creating 4 I/O queues.
nvme nvme8: Connect rejected: status 10 (stale conn).
nvme nvme8: rdma connection establishment failed (-104)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.