E系列控制器每天同时重置
适用场景
- NetApp E 系列
- 平台:E2800、E5700
- StorageGRID设备:SG57xx和SG6060
- SANtricity OS 11.70.3
问题描述
- 在收集AutoSupport数据期间、E系列控制器每天都会重新启动。
- 正常情况下、相关控制器负责处理AutoSupport。在双控制器系统中、这将是控制器B
- 受影响阵列中的主要事件日志事件示例:
B:7/14/22, 2:29:37 AM (02:29:37) 133236 2605 Start-of-day routine completed - Shelf 99, Bay B
B:7/12/22, 2:29:19 AM (02:29:19) 132986 2605 Start-of-day routine completed - Shelf 99, Bay B
B:7/9/22, 2:31:10 AM (02:31:10) 132673 2605 Start-of-day routine completed - Shelf 99, Bay B
B:7/8/22, 2:29:48 AM (02:29:48) 132488 2605 Start-of-day routine completed - Shelf 99, Bay B
B:7/7/22, 2:29:52 AM (02:29:52) 132307 2605 Start-of-day routine completed - Shelf 99, Bay B
B:7/6/22, 2:39:03 AM (02:39:03) 132155 2605 Start-of-day routine completed - Shelf 99, Bay B