E-Series iSCSI 连接频繁报告 1815/1814/180D 错误
适用于
- NetApp E-Series
- iSCSI
问题
- 控制器报告以下错误:
Event type: 1815 ISCSI carrier has been lostEvent type: 1814 ISCSI carrier has been detectedEvent type: 180D Session terminated unexpectedly
- Recovery Guru 报告
ALB_HOST_REDUNDANCY_LOST-Recovery Failure错误。 iscsi-statistics.csv在MAC receive statistics中记录大量 CRC 错误:
注: FCRCE = 帧 CRC 错误计数

STATE-CAPTURE-DATA->iscsiStateCapture->showIscsiStats(ISCSI_STATISTICS_RAW)下的错误计数器指示所有错误均来自 Rx(接收):========================================================================
ETHERNET PORT STATISTICS - PORT 0
========================================================================
Port Rx Frame CRC Err Count 0xbdef6========================================================================
IP ENDPOINT STATISTICS - PORT 0
========================================================================
IPV4 Received Pdus 0x0
IPV4 Sent Pdus 0x0
IPV4 Reassembly Required 0x0
IPV4 Fragmentation 0x0
IPV4 Fragmented Pdus Created 0x0
IPV4 Tx Byte Count 0x0
IPV4 Rx Byte Count 0x0
IPV4 Rx Error Count 0x3eff- 但目标端口 (e0a) 显示正常状态:
Hostinterface: iSCSI
HostInterfaceCard(HIC): Baseboard
Channel: 1
Port: e0a
Linkstatus: Connected