E系列-由于主机连接、卷不在首选路径上
适用场景
- NetApp E 系列
- StorageGRID
- 卷不在首选路径上(VNOPP)
问题描述
- 系统 通过
MAJOR-EVENT-LOG
中的自动卷传输(AVT)或冗余磁盘阵列控制器(RDAC)故障转移事件报告VNOPP:
Date/Time: 20XX-05-10 22:26:11
Sequence number: 69291
Event type: 4011
Event category: Error
Priority: Critical
Event needs attention: true
Event send alert: true
Event visibility: true
Description: Volume not on preferred path due to AVT/RDAC failover
Event specific codes: 0/0/0
Component type: Controller
Component location: Shelf XX, Bay X
Logged by: Controller in bay X
RECOVERY-GURU-PROCEDURES
报告NON_PREFERRED_PATH-Recovery Failure Type Code: 10
- VNOPP之前发生IO传送事件、请指定导致IO和受影响的控制器的主机:
A:5/10/XX 10:26:11 PM (22:26:11) 69291 4011 Volume not on preferred path due to AVT/RDAC failover - Shelf XX, Bay X <--CRITICAL
B:5/10/XX 10:21:11 PM (22:21:11) 69290 2044 IO shipping implicit volume transfer - Volume Volumename
----> Shipped/Owned IOs: 186360/61155, Host ID: XXX