跳转到主内容

What is meaning for Disk status was replaced with a star ico in Array Management

Views:
75
Visibility:
Public
Votes:
0
Category:
e-series-santricity-storage-manager
Specialty:
esg
Last Updated:

Applies to

  • E-Series SANtricity Storage Manager 11.30 & Prior versions

  • E-Series Controller firmware 08.30 & Prior versions

Answer

Disk status is replaced with a star ico in Array Management.

One disk has been failed manually and manual reconstruction has been performed, and then the operation of disk revive.The disk displays replaced status with a star ico in Array Management

Raid reconstruction is not completed, so the drive will stay in a replaced state until this completes.

Perform the following steps:

  1. Collect the latest Support Bundle,
  2. Check state-capture-data.txt -->vdmShowVGInfo(0,0,0,0,0,0,0,0,0,0)
  3. Find out the volume 7 with inactive drive:
    Seq:8 / RAID 5 / VGCompleteState / TLP:F / DLP:F / SSM:T / ActDrv:7 / InActDrv:1 / VolCnt:1 / Secure:No
    BlockSize:512 / LPE:0 / DBF:1 / PI Capable:T - 2 / Label:vol8 / VGWwn:60080e5000326df8000000a8541a2d27
    (Active) Drive:0x122c2ba0 devnum:0x00010033 seqNum:1 Tray/Slot:99/52 State:Acc/GrA/Opt
    (Active) Drive:0x122c3e20 devnum:0x00010034 seqNum:2 Tray/Slot:99/53 State:Acc/GrA/Opt
    (Active) Drive:0x2cc15ee0 devnum:0x00010035 seqNum:3 Tray/Slot:99/54 State:Acc/IHS/Opt
    (Active) Drive:0x122c6360 devnum:0x00010036 seqNum:4 Tray/Slot:99/55 State:Acc/GrA/Opt
    (Active) Drive:0x122c7620 devnum:0x00010037 seqNum:5 Tray/Slot:99/56 State:Acc/GrA/Opt
    (Active) Drive:0x122c88a0 devnum:0x00010038 seqNum:6 Tray/Slot:99/57 State:Acc/GrA/Opt
    (Active) Drive:0x122c9b60 devnum:0x00010039 seqNum:7 Tray/Slot:99/58 State:Acc/GrA/Opt
    (Inactive) Drive:0x122cc0a0 devnum:0x0001003b seqNum:3 State:Acc/GrA/Opt
    Volumes: 0x00007 [O]
  4. Check the volume 7 in evfShowVol-->evfShowVol(7,0,0,0,0,0,0,0,0,0)
    Background Task: COPY-BACK at block 0x00088fa4000 with 34% complete

Note: You might see the copy back or the reconstruction progress, which will always say 0% because the controller does not own that volume. The owner of the volume will show the progress.

 

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.