适用场景

  • SG57xx
  • 单工 E28xx
  • NetApp SANtricity OS 11.50.30.00+ 及更高版本

问题描述

  • 在单工设置中更换控制器时,如果尝试使用以下断言从驱动器执行自动代码同步( Auto Code Synchronisation , ACS ),则控制器将重新启动多次,并以 7 段代码 Oe LU 结束。
  • 原始控制器至少运行 11.0.30 。 xx
  • 新控制器运行的版本早于 11.56.0.xx
  • 以下条目会在 excLogShow 命令中显示多次

excLogShow

---- Log Entry #0 (Core 0) Jul-17-2021 10:20:41 AM ----

07/17/21-10:20:41 (tRAID): ASSERT: Assertion failed: false, file vdmExopExclOpAgentState.cc, line 59

2021-07-17T10:20:44.903055

Unable to determine panic string.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.