在 EF300 上添加驱动器架后第二个 SAS 连接断开
适用于
- NetApp E 系列
- EF300
- DE224C 驱动器架
问题
- 连接新驱动器架后,两个控制器上的第二个 SAS 连接均已关闭。
Drive interface: SAS Channel: 3 Part type: LSISAS3616 revision 402,653,184 Status: Up Maximum data rate: 12 Gbps Current data rate: 12 Gbps
Drive interface: SAS Channel: 4 Part type: LSISAS3616 revision 402,653,184 Status: Down Maximum data rate: 12 Gbps Current data rate: Not available
- IOMB 显示“
Optimal”状态,但不显示固件或速度详细信息。IOM status: OptimalFirmware Version: 0202Configuration settings version: Not ApplicableMaximum data rate: 12 GbpsCurrent data rate: 12 GbpsLocation: ACard communication: OKTrunking supported: NoProduct ID: DE224CBoard ID: ErmineIOM status: OptimalFirmware Version: Not AvailableConfiguration settings version: Not ApplicableMaximum data rate: Not AvailableCurrent data rate: Not AvailableLocation: BCard communication: OKTrunking supported: NoProduct ID: Not AvailableBoard ID: Not Available
- 观察到的 Recovery Guru 错误:
Failure Entry 1: LOSS_OF_EXTERNAL_REDUNDANCY-Recovery Failure Type Code: 449Storage array: Fujitsu_StorageController in bay AChannel ID: 4Controller in bay BChannel ID: 4
Failure Entry 2: LOST_REDUNDANCY_TRAY-Recovery Failure Type Code: 33Storage array: Fujitsu_StorageShelf: Drive shelf 11Working channel: 3
或
Failure Entry 1: DRIVE_TRAY_LOSS_OF_EXTERNAL_REDUNDANCY-Recovery Failure Type Code: 449Storage array: Fujitsu_StorageController in bay AChannel ID: 4Controller in bay BChannel ID: 4
Failure Entry 2: NO_REDUNDANCY_TRAY-Recovery Failure Type Code: 33Storage array: Fujitsu_StorageShelf: Drive shelf 11Working channel: 3
- 新驱动器架路径冗余丢失;只有一个路径处于活动状态。
Shelf path redundancy: Lost Current drive types: SAS Product ID: DE224C Part number: CA08733-3142