E系列系统新安装的带有Cisco SFP的iSCSI端口在配置后关闭或消失
适用场景
- E 系列
- E2860
问题描述
- 具有带 Cisco SFP 的 iSCSI 端口的新 E 系列系统安装会在配置后短暂关闭或消失。
图:我们看到基板端口 0a、0b 消失了。重新拔插线缆/SFP 或重启控制器后,它们会短暂地重新出现。
- 在控制器重新启动期间,我们在事件日志中看到:
- 注意:这可能不会从一开始就触发
B:11/20/23, 4:10:42 AM (04:10:42) 2126 2864 Host-side SFP unsupported - Shelf Unknown, Bay 0 <--CRITICAL
B:11/20/23, 4:06:14 AM (04:06:14) 2122 2864 Host-side SFP unsupported - Shelf Unknown, Bay 0 <--CRITICAL
- 在存储阵列配置文件>架子部分下:我们看到思科供应商 SFP 设置显示
Not Applicable
与其他供应商 SFP 相比
SFP status: Optimal Attached to: Host-side of controller B Location: Host port 0a Supported data rate(s): 10 Gbps Link length: Not applicable Connector: LC Transmitter type: Not applicable Transmission media: Not applicable Vendor: CISCO-OPLINK <--------- Unsupported SFP Vendor Date of manufacture: 7/11/21
SFP status: Optimal Attached to: Host-side of controller B Location: Host port 0f Supported data rate(s): 16 Gbps, 10 Gbps, 8 Gbps, 4 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) Vendor: AVAGO Date of manufacture: 11/9/22
注意 - 在控制器重新启动之前,可能不会看到 SFP 不支持事件