E系列系统Cisco SFP出现故障或配置后消失的全新安装iSCSI端口
适用场景
- E 系列
- E2860
问题描述
- 如果在新安装的E系列系统中安装了iSCSI端口和Cisco SFP、 则在配置后会关闭或短暂消失。
图:我们看到底板端口0a、0b已消失。重新拔插缆线/SFP或重新启动 控制器后、它们会短暂重新出现。
- 在控制器重新启动期间、我们会在事件日志中看到:
- 注意:这可能不会从开始时触发
B:11/20/23, 4:10:42 AM (04:10:42) 2126 2864 Host-side SFP unsupported - Shelf Unknown, Bay 0 <--CRITICAL
B:11/20/23, 4:06:14 AM (04:06:14) 2122 2864 Host-side SFP unsupported - Shelf Unknown, Bay 0 <--CRITICAL
- 在 “存储阵列配置文件”> “磁盘架”部分下: 我们看到Cisco供应商的SFP设置
Not Applicable
与其他供应商的SFP相比较
SFP status: Optimal Attached to: Host-side of controller B Location: Host port 0a Supported data rate(s): 10 Gbps Link length: Not applicable Connector: LC Transmitter type: Not applicable Transmission media: Not applicable Vendor: CISCO-OPLINK <--------- Unsupported SFP Vendor Date of manufacture: 7/11/21
SFP status: Optimal Attached to: Host-side of controller B Location: Host port 0f Supported data rate(s): 16 Gbps, 10 Gbps, 8 Gbps, 4 Gbps Link length: Short Connector: LC Transmitter type: Shortwave Laser w/o OFC Transmission media: TM Multi-mode 50m(M5) Vendor: AVAGO Date of manufacture: 11/9/22
注-在控制器重新启动之前、可能看不到SFP不受支持的事件