E-Series警报、其中包含多个降级的SAS错误
适用场景
E 系列
问题描述
- 阵列会报告多个组件(包括驱动器通道和端口)的多个SAS相关严重事件。
E-Series Notification (An IOM (ESM) has reported an exception event) WARNING
E-Series Notification (Drive channel set to Degraded) CRITICAL
E-Series Notification (Controller wide port has gone to failed state) CRITICAL
E-Series Notification (Drive channel set to Degraded) CRITICAL
E-Series Notification (Controller redundancy lost) CRITICAL
E-Series Notification (Drive tray path redundancy lost) CRITICAL
E-Series Notification (Degraded wide port becomes failed) CRITICAL
- IOM指示灯呈琥珀色。
- 系统处于已禁用写入缓存的降级状态。
示例:
Degraded drive paths:
Channel: 2
Related drives (Shelf, Bay): (0, 2)
Storage array:
Port reporting problem:
Drive shelf 0, IOM: B (Right), Port: Port 2
Status: SAS Port Degraded
Degraded drive channel: 2
Port reporting problem:
Controller B, Internal connection
Status: SAS Port Degraded