跳转到主内容

E系列控制器缓存电池出现故障—AutoSupport 消息

Views:
73
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

适用场景

NetApp E 系列

事件摘要

恢复大师中的SANtricity错误: FAILED_BATTERY-Recovery Failure Type Code: 6 

验证

  • Recovery-Guru-Procedures 文件显示的故障条目 FAILED_BATTERY-Recovery Failure Type Code: 6

E系列控制器缓存电池出现故障- AutoSupport消息

  • majer-event-log 文件显示 Controller cache battery failedEvent Type 210C

E系列控制器缓存电池出现故障

  • SHELVES storage-array-profile 文件中的部分将电池状态显示为 Failed

示例:

     Battery status:        Failed       
     Location:           Controller B     
     Age:              1,825 days      
     Days until replacement:    Not applicable    
     Last learn cycle:       2021/01/21      
     Next learn cycle:       2021/03/18      
     Weeks between learn cycles:  8           
     Part number:          PN 36540-06      
     Serial number:        <SERIAL NUMBER>   
     Vendor:            VN LSI        
     Date of manufacture:      2015/07/01   

  • bidShow(255,0,0,0,0,0,0,0,0,0) STATE-CAPTE-DATA文件中的命令输出提供了有关电池故障的更多详细信息、包括其安全状态。以下示例显示了导致其故障的蓄电池欠压安全状态已触发。
    • CUV:电池电压不足
    • CUVC:电池电压不足
    • COV:电池过电压
    • OCC#:充电电流过大 #
    • OCC:充电恢复中的过电流
    • OCD#:放电时过流 #
    • OCD:放电恢复中的过流
    • AOLD:放电时过载
    • ASCC:充电时短路
    • ASCD:放电时短路
    • OTC:充电温度过高
    • OTD:放电时温度过高
    • UTC:充电温度过低
    • UTD:放电时温度过低

SafetyStatus:      0x00000001 [ CUV ]

解决方法

  1. 更换之前,必须先评估任何BBU故障,以确保当前控制器代码正在运行​​​​​ 系统必须运行08.40.60.01或更高版本。
  2. 如果控制器固件不是上述最新版本、则必须先更新固件。
  3. 更新固件后、必须运行新的手动记忆周期 - 如何使用SANtricity手动启动电池记忆周期
    1. 在极少数情况下、可能需要运行两次才能完全恢复受先前降速代码问题影响的电池。
  4. 如果上述问题均无法解决问题描述问题、请联系NetApp技术支持、因为可能需要更换。 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.