托盘中的抽屉因控制器故障而降级
适用于
- E-series
- 仅限控制器机架(不适用于扩展机架中的抽屉)
问题
- 主要事件日志 (MEL) 报告磁盘架中的某个抽屉已降级。
A:9/28/23 6:14:13 AM (06:14:13) 37166 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 5 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37165 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 4 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37164 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 3 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37163 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 2 <--CRITICAL
A:9/28/23 6:14:13 AM (06:14:13) 37162 285f A drawer in the shelf has become degraded - Shelf 99, Drawer 1 <--CRITICAL
A:9/28/23 6:13:42 AM (06:13:42) 37161 282b Drive shelf path redundancy lost - Shelf 99 <--CRITICAL
State-capture-data>ionShow99>luall 0报告路径缺失(黄色部分为空):
00010101 t99,s2 SASdr :+++ : + + : 16 0 0 14522 0 : 0 00010102 t99,s3 SASdr :+++ : + * : 16 0 0 10402 0 : 0 00010103 t99,s4 SASdr :+++ : * + : 16 0 0 6042 0 : 0
- MEL 还报告控制器已移除:
A:9/28/23 6:13:09 AM (06:13:09) 37158 2500 Controller removed - Shelf 99, Bay B <--CRITICAL - 受影响的控制器未手动移除,但无响应。