由于FC链路故障、导致"主机端连接冗余丢失"
适用场景
- NetApp E 系列
- 光纤通道连接
问题描述
- 系统生成警报报告、并在控制器 重新启动后持久保留:
Loss of host-side connection redundancy detected- RECOVERY-GURU-PROCEDURES.HTML中的错误:
ALB_HOST_REDUNDANCY_LOST-Recovery Failure Type Code: 475
- Major Event Logs PARSER中的错误:
Loss of host-side connection redundancy detected - Host hostname <--CRITICAL
Volume not on preferred path due to AVT/RDAC failover - Shelf XX, Bay X <--CRITICAL
- 一个控制器的端口0a和0b上的FC链路已关闭: 
Host interface:                  Fibre
          Host Interface Card(HIC):     Baseboard
          Channel:                      1
          Port:                        0a, 0a
          Current ID:                   Not applicable/0xFFFFFFFF
          Preferred ID:                 0/0xEF
          NL-Port ID:                   0xFFFFFF
          Maximum data rate:            16 Gbps
          Current data rate:            Not available
          Data rate control:            Auto
          Link status:                 Down
Host interface:                  Fibre
          Host Interface Card(HIC):     Baseboard
          Channel:                      2
          Port:                        0b, 0b
          Current ID:                   Not applicable/0xFFFFFFFF
          Preferred ID:                 1/0xE8
          NL-Port ID:                   0xFFFFFF
          Maximum data rate:            16 Gbps
          Current data rate:            Not available
          Data rate control:            Auto
          Link status:                 Down
- 在出现"主机端连接冗余丢失"错误之前、端口0A 已启动