E系列电源故障 - 无电源输入
适用场景
- NetApp E 系列
- StorageGRID设备
问题描述
- Recovery Guru报告:
Failure Entry 1: SUPPORT_CRU_NOINPUT-Recovery Failure Type Code: 97
 Storage array: E2812
 Component reporting problem: Power supply canister (Right)
 Status: No power input
 Location: Controller/Drive shelf 99
 Component requiring service: Power supply canister (Right)
 Service action (removal) allowed: Yes
 Service action LED on component: No
 Subcomponent affected: Power supply (99)
- 存储阵列配置文件显示电源风扇仓和电源没有电源输入:
Power-Fan Canisters Detected:  2
          Power-fan canister (Left) status:  Optimal          
          Part number:                       114-00148+E0     
          Serial number:                     111111111111111  
          Date of manufacture:               Not Available    
         Power-fan canister (Right) status:  No AC power input  
          Part number:                        114-00148+E0       
          Serial number:                      222222222222222    
          Date of manufacture:                Not Available 
- 对于电源容器中也包含风扇的系统(即 SG5712、E2812),Recovery Guru 中也会报告以下故障:
Failure Entry 1: SUPPORT_CRU_NOINPUT-Recovery Failure Type Code: 97
 Storage array: E2812
 Component reporting problem: Power supply canister (Right)
 Status: No power input
 Location: Controller/Drive shelf 0
 Component requiring service: Power supply canister (Right)
 Service action (removal) allowed: Yes
 Service action LED on component: No
- 如果启用了 AutoSupport,系统会向最终用户发送电子邮件。作为回报,如果需要创建支持案例,用户有 24 小时的时间回复。电子邮件通知将用于: E-Series Notification (Power supply failed) CRITICAL- 从 SANtricity OS 11.70.3 开始,如果电源故障原因是电源输入丢失,则不会发送 AutoSupport 消息。但是,如果在 SANtricity System Manager 中配置了电子邮件通知( 配置警报的邮件服务器和收件人),则会向最终用户发送电子邮件。
 
- StorageGRID 系统管理器报告以下警报:- Appliance overall power supply degraded
- Appliance storage shelves degraded
- Appliance storage controller hardware issue