跳转到主内容

在控制器重新启动后标记为不安全的卷组

Views:
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

适用场景

SANtricity 11.80 GA之前的版本

问题描述

  • 重新启动控制器后、一个卷组将从安全状态变为非安全状态。
  • 重新启动前vdmShowVGInfo  会将 两个控制器中的卷组显示为已启用FIPS:

控制器A
Seq:20 / RAID 5 / VGCompleteState / TLP:F / DLP:T / SSM:T / ActDrv:12 / InActDrv:0 / VolCnt:2 / Secure:FIPS_ENABLED / DULBE:No
BlockSize:512 / LPE:3 / DBF:2 / PI Capable:T - 2 / Label:VolumeGroup / VGWwn:xxxxxxxxxxxxxxxxxxx / RsvdSpace: 5 (GB)



控制器B
Seq:20 / RAID 5 / VGCompleteState / TLP:F / DLP:T / SSM:T / ActDrv:12 / InActDrv:0 / VolCnt:2 / Secure:FIPS_ENABLED / DULBE:No
BlockSize:512 / LPE:3 / DBF:2 / PI Capable:T - 2 / Label:VolumeGroup / VGWwn:xxxxxxxxxxxxxxxxxxxxxxx / RsvdSpace: 5 (GB)

  • 重新启动后、两个控制器都会将卷组标记为无安全:

控制器A
Seq:20 / RAID 5 / VGCompleteState / TLP:F / DLP:T / SSM:T / ActDrv:12 / InActDrv:0 / VolCnt:2 / Secure:No / DULBE:No
BlockSize:512 / LPE:3 / DBF:2 / PI Capable:T - 2 / Label:VolumeGroup / VGWwn:xxxxxxxxxxxxxxxxxxxxxxx / RsvdSpace: 5 (GB)



控制器B
Seq:20 / RAID 5 / VGCompleteState / TLP:F / DLP:T / SSM:T / ActDrv:12 / InActDrv:0 / VolCnt:2 / Secure:No / DULBE:No
BlockSize:512 / LPE:3 / DBF:2 / PI Capable:T - 2 / Label:VolumeGroup / VGWwn:xxxxxxxxxxxxxxxxxxxxxxx / RsvdSpace: 5 (GB)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.