E系列 SAS 端口在热添加扩展后降级
适用于
- E 系列
 - SANtricity OS
 
问题描述
- 在热添加扩展之后,Recovery Guru 报告了以下内容:
 
Failure Entry 1: SAS_PORT_DEGRADED-Recovery Failure Type Code: 112
 Port reporting problem:
 Drive shelf 3, Drawer 4, Channel 3, Internal connection
 Status: SAS PortDegraded
Failure Entry 2: SAS_PORT_DEGRADED-Recovery Failure Type Code: 112
 Port reporting problem:
 Drive shelf 3, IOM: B (Bottom), Channel 3, Internal connection
 Status: SAS Port Degraded
- 在 
STATE-CAPTURE-DATA>sasStateCapture>sasShowEncls报告两个控制器缺少到货架的连接。 
sasshowEncls: A SAS level of -1 indicates no connection
Tray :  SASLevel   :     View From Ctlr A      : Enclosure
    ID : CtlrA  CtlrB : ch#/expDevH  ch#/expDevH : Logical ID
  ---- : -----  ----- : ------------ ------------ :----------------
     0 :     2     4 : ch0 /0x11    ch0 /0x15f   : 500a09800ebc5da1
     0 :     5     5 : ch0 /0x26a   ch1 /0xd8    : 500a09800ecadd58
     1 :     3     4 : ch0 /0x2e    ch1 /0xbb    : 500a09800ec8939d
     2 :   -1      3 : ch1 /0       ch1 /0x1a2   : 500a09800ec9367e
     3 :   -1      2 : ch1 /0       ch1 /0x2ad   : 500a09800ecadd58
    99 :     1     1 : ch0 /0x9     ch1 /0xb3    : 0000000000000000
sasshowEncls: A SAS level of -1 indicates no connection
Tray :  SASLevel   :     View From Ctlr B      : Enclosure 
    ID : CtlrA  CtlrB : ch#/expDevH  ch#/expDevH : Logical ID
  ---- : -----  ----- : ------------ ------------ :----------------
     0 :     2     4 : ch0 /0x19    ch0 /0x15f   : 500a09800ebc5da1
     0 :     5     5 : ch0 /0x26a   ch1 /0x54    : 500a09800ecadd58
     1 :     3     4 : ch0 /0x53    ch1 /0x1a    : 500a09800ec8939d
     2 :   -1      3 : ch-1/0       ch1 /0x1a2   : 500a09800ec9367e
     3 :   -1      2 : ch-1/0       ch1 /0x2ad   : 500a09800ecadd58
    99 :     1     1 : ch0 /0x9     ch1 /0xa     : 0000000000000000
- 所有抽屉和驱动器都按预期在 
sasStateCapture>sasShowAllExpanders中列出