错误地报告 E 系列电源故障严重
适用场景
- SG5712
- 电源固件 01.10
问题描述
- 在这种情况下
STORAGE-ARRAY-PROFILE
,电源 1 出现故障的原因是 -SHELVES
:
Power Supplies Detected: 2
Power supply status: Failed
Location: Left
Part number: 114-00148+F1
Serial number: Serial number
Date of manufacture: Not Available
STATE-CAPTURE-DATA
—evfShowVol
ssmShowSubTree
—显示 PSU 1 状态正常:
[Power Supply]
Status: Okay
Access Path Status: Okay
Swapped?: No
Predicted Fail?: No
...
Slot: 1
Parent Slot: 1
Relative Slot: 1
Relative Parent Locations: Enclosure(1) Support CRU(1)
...
Component Reported: Yes
Error Rep When Missing: Yes
Attn Request / Attn On: No / No
...
Fault LED On?: No
Additional Failure?: No
Requested On?: Yes
Off?: No
Has Power Input?: Yes
DC Under Voltage?: No
DC Failed?: No
...
Firmware Revision: 01.10
- 之后,错误消息消失,
STORAGE-ARRAY-PROFILE
并将电源状态显示回Optimal
:
Power Supplies Detected: 2
Power supply status: Optimal
Location: Left
Part number: 114-00148+F1
Serial number: Serial number
Date of manufacture: Not Available