跳转到主内容

已强制禁用回写缓存、但BBU损坏

Views:
15
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg<a>2009-164396</a>
Last Updated:

适用场景

  • SANtricity系统
  • E2724
  • E2860

问题描述

  • MEL解析器已解码MEL、 已对损坏的BBU (电池备用单元)强制禁用回写缓存。

示例:

A:5/9/22 6:53:02 PM (09:53:02) 66045 212b Write-back caching forcibly disabled - Tray 99, Slot A - Event: BAD BBU-0,1,2,3,4,5,6,7,8,9,10,11 <--CRITICAL
A:5/9/22 6:37:58 PM (09:37:58) 66044 210a Controller cache not enabled or was internally disabled - Tray 99, Slot A - Event: BAD BBU,Battery Unusable-0
A:5/9/22 6:37:58 PM (09:37:58) 66043 7302 Low battery capacity - Tray 99, Controller 1, Slot 1 - 27C, 6.94V, 2010mAH

  • 如中所示,需要更换电池 Storage Array Profile

示例:

Battery status:        Battery replacement required
Location:           Controller A
Age:              2,812 days
Days until replacement:    Not applicable
Last learn cycle:       4/14/22
Next learn cycle:       6/9/22
Weeks between learn cycles:  8
Part number:          PN 36540-06
Serial number:         SN SY41240573A1
Vendor:            VN LSI
Date of manufacture:      3/1/14

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.