E系列驱动器更换后无响应
适用于
- NetApp E 系列
- 所有固件版本
- 磁盘驱动器已更换
问题描述
- 在 STORAGE-ARRAY-PROFILE中驱动器在更换后显示无响应
    SHELF, DRAWER, BAY  STATUS     CAPACITY   MEDIA TYPE     INTERFACE TYPE  CURRENT DATA RATE  PRODUCT ID     FIRMWARE VERSION  CAPABILITIES  
     99,   4,    6   Optimal     10.692 TB  Hard Disk Drive  SAS        12 Gbps       HUH721212AL5204  NE00        DA
     99,   4,    7   Unresponsive
     99,   4,    8   Optimal     10.692 TB  Hard Disk Drive  SAS        12 Gbps       HUH721212AL5204  NE00        DA
- Recovery Guru 消息还显示无响应磁盘
Failure Entry 4: FAILED_DRIVE-Recovery Failure Type Code: 23
 Storage array: ArrayName
 Component reporting problem: Drive in bay 0
 Status: Unresponsive
 Location: Controller/Drive shelf 0, Drawer 0