跳转到主内容

E系列控制器意外脱机并使用操作系统L3进行操作

Views:
29
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg<a>2009年471545</a>
Last Updated:

适用场景

NetApp E 系列 E2800

问题描述

  • 控制器脱机、无法使用锁定代码启动 OE L3
  • Major-Event Log 显示以下消息:
    • A:2/11/23, 7:10:16 AM (07:10:16) 59865 6107 This controller's alternate is non-functional and is being held in reset - Shelf 99, Bay B <--CRITICAL
      A:2/11/23, 7:10:16 AM (07:10:16) 59864 2829 Controller redundancy lost - Shelf 99, Bay A <--CRITICAL
      A:2/11/23, 7:10:16 AM (07:10:16) 59863 400f Controller reset by its alternate - Shelf 99, Bay B
      ----> Reboot Reason : CMGR: REBOOTALT_CMGR_SET_ALT_TO_FAILED
      A:2/11/23, 7:10:16 AM (07:10:16) 59862 400c Controller placed offline - Shelf 99, Bay B
      ----> Reboot Reason : CMGR: REBOOTALT_CMGR_SET_ALT_TO_FAILED
      [Status changed from Unassigned to Active]
  • 连接串行电缆会重复显示错误消息、如下所示:
    • 00000000000000 RSI: ffffffff820bcc60 RDI: 0000000000000003
      [ 2821.457342] RBP: ffffe8ffffd91fa0 R08: 0000000000000004 R09: 0000000000025d80
      [ 2821.464436] R10: 0000002c718cd5dc R11: ffff8880777a5628 R12: 0000000000000004
      [ 2821.471531] R13: ffffffff820bcdf8 R14: 0000000000000004 R15: 0000000000000000
      [ 2821.478628]  cpuidle_enter_state+0x6c/0x310
      [ 2821.482786]  do_idle+0x218/0x250
      [ 2821.485994]  cpu_startup_entry+0x6f/0x80
      [ 2821.489892]  start_secondary+0x186/0x1e0
      [ 2821.493790]  secondary_startup_64+0xa4/0xb0
      [ 2821.497948] bad: scheduling from the idle thread!
      [ 2821.502624] CPU: 3 PID: 0 Comm: swapper/3 Tainted: G    D W  O    4.19.0-19-clp-eseries-amd64 #1 Debian 4.19.232-1+clp+40+eseries31
      [ 2821.514731] Hardware name: Default string Default string/Default string, BIOS 2.04.0 05/04/2018
      [ 2821.523379] Call Trace:
      [ 2821.525809]  dump_stack+0x66/0x81
      [ 2821.529103]  dequeue_task_idle+0x24/0x30
      [ 2821.533002]  __schedule+0x2f2/0x7f0
      [ 2821.536468]  schedule+0x28/0x80
      [ 2821.539587]  schedule_timeout+0x262/0x3a0
      [ 2821.543572]  __down_interruptible+0xba/0xf0
      [ 2821.547729]  ? msg_print_text+0x70/0x100
      [ 2821.551626]  down_interruptible+0x42/0x50
      [ 2821.555610]  pstore_dump+0x9e/0x330
      [ 2821.559076]  ? vprintk_emit+0x209/0x260
      [ 2821.562889]  ? printk+0x58/0x6f
      [ 2821.566011]  kmsg_dump+0xb0/0xd0
      [ 2821.569218]  oops_end+0x64/0xc0
      [ 2821.572339]  no_context+0x1bc/0x380
      [ 2821.575806]  __do_page_fault+0xa2/0x4c0
      [ 2821.579617]  ? wait_for_xmitr+0x3a/0xa0
      [ 2821.583428]  ? number+0x320/0x360
      [ 2821.586723]  ? number+0x320/0x360
      [ 2821.590017]  page_fault+0x1e/0x30
      [ 2821.593309] RIP: 0010:compress_block+0x29d/0x450
      [ 2821.597898] Code: 44 89 d1 44 29 e1 d3 fb 41 8d 4c 2c f0 66 89 9f 20 17 00 00 41 89 d8 89 8f 24 17 00 00 42 8b 1c 9d 60 46 c7 81 85 db 0f 84 37 <01> 00 00 42 2b 04 9d e0 c6 5b 82 45 89 d3 41 29 db 41 39 cb 0f 8d

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.