E-Series A 托盘中的抽屉已降级 - AutoSupport 消息
适用于
- NetApp E 系列
- StorageGRID 设备 SG6060、SG5760
事件摘要
- 生成的 AutoSupport 消息标题为:
E-Series Notification from E2860 (A drawer in the tray has become degraded) CRITICAL。
- 生成具有以下症状的相关案例:
EHWENC:E-Series Notification from E2860 (A drawer in the tray has become degraded) CRITICAL
验证
- 登录 SANtricity Storage Manager 或 SANtricity System Manager
- 确认 SANtricity 在 Recovery GURU 中报告以下错误消息之一:
DRAWER_DEGRADED-Recovery Failure Type Code: 393 - 确认是否为主要事件日志 (MEL)
A:12/22/21 12:07:56 PM (11:07:56) 401865 285f A drawer in the tray has become degraded - Tray 1, Drawer 3 <--CRITICAL
- 从 Hardware 选项卡确认抽屉显示为已降级
- 在
Storage array profile中确认抽屉状态。示例:
Drawers Detected: 3Drawer status: Optimal
Position: 1
Part number: PN 111-03261
Serial number: SN xxxxxxxx
Manufacturer: VN NETAPP
Date of manufacture: 11/1/16
FRU Type: FT SASDRWR
Drawer status: Optimal
Position: 2
Part number: PN 111-03261
Serial number: SN xxxxxxxx
Manufacturer: VN NETAPP
Date of manufacture: 11/1/16
FRU Type: FT SASDRWR
Drawer status: Degraded
Position: 3
Part number: PN 111-03261
Serial number: SN xxxxxxxx
Manufacturer: VN NETAPP
Date of manufacture: 11/1/16
FRU Type: FT SASDRWR
解决方法
- 请确保不存在其他硬件问题,例如可能导致此事件的降级/故障控制器。
- 尝试重新拔插抽屉与机箱之间的柔性电缆(SAS Snake 电缆)。
- 请联系NetApp 技术支持,因为如果重新拔插不起作用,则可能需要更换抽屉