为什么在StorageGRID升级时、由于无法满足EC所需的最低节点数、ILM放置不可实现警报未出现?

Views:
2
Visibility:
Public
Votes:
0
Category:
storagegrid
Specialty:
sgrid
Last Updated:

适用场景

StorageGRID  11.5或更高版本

问题解答

升级时、加载对象大小可能小于1 MB、因此、系统甚至不会检查使用EC配置文件的ILM规则、而是根据小于1 MB的对象的复制副本执行加载。
如果发生了建议、并且未满足ILM规则、则会生成警报、但由于对象大小较小、甚至不会检查EC配置文件的ILM规则。
因此、在升级时未为此站点生成任何警报。

您可以使用Audit-解释 工具在升级期间检查对象大小(以字节为单位)。

追加信息

Audy-讲解 工具

 

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.