安装SnapCenter服务器后缺少插件软件包
适用场景
- SnapCenter服务器4.9 (SC)
- SnapCenter服务器4.9P1 (SC)
- 任何SnapCenter插件安装
问题描述
- 无法为SC安装任何插件软件包、因为此
C:\ProgramData\NetApp\SnapCenter\Package Repository
文件夹作为Integrity_verifier
日志为空或SC_Package_Extraction_Log_<timestamp>.log
在上述目录中显示零个文件:
Total files to be checked - 1215
Enter method GetDirectoryFileInfoList
-Include NetApp files - False
-Path used - C:\ProgramData\NetApp\SnapCenter\Package Repository, File count - 0
InstallShield
日志显示安装无法打开DLL程序集文件:
(CLR Action): Using highest version runtime...
(CLR Action): cannot open assembly file C:\Users\CFA028\AppData\Local\Temp\2\{6DB7C6CA-C7A0-451A-B6D3-D0B9789CD2C0}\BundleCSActions.dll
Action returned value 0x00000643
Action 'Create_SnapCenterID_File' returned status 0x80070643
UI DLL: Display Error: Fatal error during installation.
Error code: 0x80070643
(CLR Action): cannot open assembly file C:\Users\CFA028\AppData\Local\Temp\2\{6DB7C6CA-C7A0-451A-B6D3-D0B9789CD2C0}\BundleCSActions.dll
Action returned value 0x00000643
Action 'ShowLogFiles' returned status 0x80070643
Original exit status: 0x80070643, final exit status: 0x00000643
- 此
InstallShield
日志显示某些PowerShell脚本在安装SC服务器期间失败:
(ISP Action): szCommandLineResult = C:\Windows\sysnative\windowspowershell\v1.0\powershell.exe -ExecutionPolicy Bypass -file "C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1" stop
ISP Action): TEMP = C:\Users\scuser\AppData\Local\Temp
(ISP Action): OpenFile failed.
Action returned value 0x00000000
- 最后、上述错误后的回滚也会失败:
Action 'RollbackSMS' returned status 0x80070643
UI DLL: Shutting down
Original exit status: 0x80070643, final exit status: 0x00000643
- 从管理的PS cmdlet窗口手动尝试相同的PS脚本会生成以下错误:
PS C:\Windows\system32> powershell.exe -ExecutionPolicy Bypass -file "C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1"
File C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1 cannot be loaded. The file
C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1 is not digitally signed. You cannot run this script on the current system. For more information about running scripts and setting execution policy, see about_Execution_Policies
at https:/go.microsoft.com/fwlink/?LinkID=135170.
- 尽管存在上述所有错误、但SC服务器安装仍显示为已完成、并且在图形用户界面中登录时、SC服务器安装脚本或SC中未报告任何错误。