跳转到主内容

安装SnapCenter服务器后缺少插件软件包

Views:
5
Visibility:
Public
Votes:
0
Category:
snapcenter
Specialty:
snapx<a>2009年888134</a>
Last Updated:

适用场景

  • SnapCenter服务器4.9 (SC)
  • SnapCenter服务器4.9P1 (SC)
  • 任何SnapCenter插件安装

问题描述

  • 无法为SC安装任何插件软件包、因为此 C:\ProgramData\NetApp\SnapCenter\Package Repository 文件夹作为 Integrity_verifier 日志为空或 SC_Package_Extraction_Log_<timestamp>.log 在上述目录中显示零个文件:

Total files to be checked - 1215
Enter method GetDirectoryFileInfoList
-Include NetApp files - False
-Path used - C:\ProgramData\NetApp\SnapCenter\Package Repository, File count - 0

  • InstallShield 日志显示安装无法打开DLL程序集文件:

(CLR Action): Using highest version runtime...
(CLR Action): cannot open assembly file C:\Users\CFA028\AppData\Local\Temp\2\{6DB7C6CA-C7A0-451A-B6D3-D0B9789CD2C0}\BundleCSActions.dll
Action returned value 0x00000643
Action 'Create_SnapCenterID_File' returned status 0x80070643
UI DLL: Display Error: Fatal error during installation.
Error code: 0x80070643
(CLR Action): cannot open assembly file C:\Users\CFA028\AppData\Local\Temp\2\{6DB7C6CA-C7A0-451A-B6D3-D0B9789CD2C0}\BundleCSActions.dll
Action returned value 0x00000643
Action 'ShowLogFiles' returned status 0x80070643
Original exit status: 0x80070643, final exit status: 0x00000643

  • InstallShield 日志显示某些PowerShell脚本在安装SC服务器期间失败:

(ISP Action): szCommandLineResult = C:\Windows\sysnative\windowspowershell\v1.0\powershell.exe -ExecutionPolicy Bypass -file "C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1" stop
ISP Action): TEMP = C:\Users\scuser\AppData\Local\Temp
(ISP Action): OpenFile failed.
 Action returned value 0x00000000

  • 最后、上述错误后的回滚也会失败:

Action 'RollbackSMS' returned status 0x80070643
UI DLL: Shutting down
Original exit status: 0x80070643, final exit status: 0x00000643

  • 从管理的PS cmdlet窗口手动尝试相同的PS脚本会生成以下错误:

PS C:\Windows\system32> powershell.exe -ExecutionPolicy Bypass -file "C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1"
File C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1 cannot be loaded. The file
C:\Users\scuser\AppData\Local\Temp\{E6F11169-0D23-43F6-902B-B37CC232DF5E}\RestartSCSite.ps1 is not digitally signed. You cannot run this script on the current system. For more information about running scripts and setting execution policy, see about_Execution_Policies

at https:/go.microsoft.com/fwlink/?LinkID=135170.

  • 尽管存在上述所有错误、但SC服务器安装仍显示为已完成、并且在图形用户界面中登录时、SC服务器安装脚本或SC中未报告任何错误。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.