跳转到主内容

H610S支持单个NVDIMM配置

Views:
8
Visibility:
Public
Votes:
0
Category:
h-series
Specialty:
hci
Last Updated:

适用场景

NetApp H610S

问题描述

  • Element软件版本12.7和存储固件包版本2.164增加了对H610S节点中单个NVDIMM的支持

  • 如果在具有单个NVDIMM的节点上执行低于12.7的传统RTFI (tRTFI)、则在RTFI过程中将出现以下错误:

Verifying MEMORY_GB actual=[720] >= expect=[736]
[MEMORY_GB] mismatch -- actual=[720] >= expect=[736]

NUM_NVRAM_DEVS actual=[1] == expect=[2]
[NUM_NVRAM_DEVS] mismatch -- actual=[1] == expect=[2]

SMART_CAPACITY actual=[16G] == expect=[32G]
[SMART_CAPACITY] mismatch -- actual=[16G] == expect=[32G]

There were 3 hardware related RTFI_HARDWARE_FAILURES
+----------------+--------+----+----------+--------+
| Tag            | Actual | Op | Expected | Passed |
+----------------+--------+----+----------+--------+
| MEMORY_GB      | 720    | >= | 736      | 0      |
|----------------|--------|----|----------|--------|
| NUM_NVRAM_DEVS | 1      | == | 2        | 0      |
|----------------|--------|----|----------|--------|
| SMART_CAPACITY | 16G    | == | 32G      | 0      |
+----------------+--------+----+----------+--------+

>> [UnhandledError pid=2641 cmd= return ${#RTFI_HARDWARE_FAILURES[@]}]
   :: sfhwcheck:11          | main
 
hardware_check failed
Ignore errors and continue (ALT-F8 to display, ALT-F7 to return) (Yes,No)

  • 如果用户输入"是"、则RTFI过程应完成、不会再出现任何问题、但在将节点添加到集群后、将为该节点记录以下错误:

hardwareConfigMismatch      MEMORY_GB should be >= 736 but is 720

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 