H610S BIOS错误重新启动(到期时使用计时器:BIOS FRB 2)
适用场景
- NetApp H系列节点:H610S
问题描述
- 使用BMC控制台、崩溃购物车或BMC - IPMI日志可以看到此错误。
- BMC SEL日志:
Watchdog 2: power cycle (timer use at expiration: BIOS FRB2)- Asserted
- BMC SEL日志:
Event ID Time Stamp Severity Sensor Name Sensor Type Description 239 Oct/24/2022 19:03:32 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted 238 Oct/24/2022 19:03:17 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Asserted 237 Oct/24/2022 19:03:12 [Warning] [Watchdog] [Watchdog 2] Power Cycle(Timer use at expiration: BIOS FRB2) - Asserted 236 Oct/24/2022 18:47:01 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted 235 Oct/24/2022 18:46:45 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Asserted 234 Oct/24/2022 18:46:40 [Warning] [Watchdog] [Watchdog 2] Power Cycle(Timer use at expiration: BIOS FRB2) - Asserted 233 Oct/24/2022 18:30:29 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted 232 Oct/24/2022 18:30:13 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Asserted 231 Oct/24/2022 18:30:09 [Warning] [Watchdog] [Watchdog 2] Power Cycle(Timer use at expiration: BIOS FRB2) - Asserted 230 Oct/24/2022 18:13:57 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Deasserted 229 Oct/24/2022 18:13:41 [Information] [Power Unit] [Power Unit] Power Off / Power Down - Asserted