尝试 CVO 升级时 BlueXP 连接器超时
适用于
- BlueXP Connector
- Cloud Volumes ONTAP (CVO)
问题描述
- 从 BlueXP 启动的 CVO 升级失败。升级尝试完成后,CVO 会重新启动,但不会执行升级。
- 查看连接器服务器日志表明 CVO 尝试下载系统映像时出现超时错误:
2022-03-22 17:26:32,808 UTC ERROR [Update System Image ] [6aSqaR74] [6aSqaR74 ] [USER ] (simplicator-akka.actor.default-dispatcher-28440) [SimplicatorServerActor:285] ******************** Simplicator request to http://localhost:8080/ZapiProtocol/downloadClusterImage failed: Data retrieval failed from remote host "http://<ip-address>:80/ontap/images/ONTAP-9.8.tgz". Reason: Timeout was reached : Connection timed out after 60005 milliseconds
com.netapp.oncloud.simplicator.client.common.SimplicatorException: Data retrieval failed from remote host "http://<ip-address>:80/ontap/images/ONTAP-9.8.tgz". Reason: Timeout was reached : Connection timed out after 60005 milliseconds
- 运行以下命令时,ONTAP 版本将反映当前版本而不是升级版本:
::> version