适用场景

AFF A200

问题描述

  • 两个节点上的系统故障LED均呈琥珀色。

示例:

200::*> system controller service-event show
               
Node        ID  Event Location            Event Description
---------------- --- ----------------------------------  ----------------------
A200-01      1   Chassis 1               SAS Expander has set the Chassis LED ON
A200-02      1   Chassis 1               SAS Expander has set the Chassis LED ON

  • 模块A/B扩展器温度显示故障。

示例:

A200::*> system node environment sensors show

Node Sensor          State Value/Units Crit-Low Warn-Low Warn-Hi Crit-Hi
---- --------------------- ------ ----------- -------- -------- ------- -------
A200-01
   CPU0 Temp Margin    
            init-failed
                     - C      -     -     0    -1
   CPU0 Core Temp     normal
                    38 C      0     5    90    100
   PCM_Inlet_Temp     normal
                    28 C      0     5    67    72
A200-02
   PSU2 FRU        normal
                     GOOD
   PSU1 FRU        normal
                     GOOD
   SP Status        normal
                  IPMI_HB_OK
   Partner Status     
           not-available
   PSU1 Present      
           not-available
   PSU1 5V         
           not-available
                     - mV      -     -     -     -
   PSU1 12V        
           not-available
                     - mV      -     -     -     -
   PSU1 5V Curr      
           not-available
                     - mA      -     -     -     -
   PSU1 12V Curr      
           not-available
                     - mA      -     -     -     -
   PSU1 Fan 1       
           not-available
                     - RPM     -     -     -     -
   PSU1 Fan 2       
           not-available
                     - RPM     -     -     -     -
   PSU1 Inlet Temp     
           not-available
                     - C      0     5    57    62
   PSU1 Hotspot Temp    
           not-available
                     - C      0     5    90    100
   PSU2 Present      
           not-available
   PSU2 5V         
           not-available
                     - mV      -     -     -     -
   PSU2 12V        
           not-available
                     - mV      -     -     -     -
   PSU2 5V Curr      
           not-available
                     - mA      -     -     -     -
   PSU2 12V Curr      
           not-available
                     - mA      -     -     -     -
   PSU2 Fan 1       
           not-available
                     - RPM     -     -     -     -
   PSU2 Fan 2       
           not-available
                     - RPM     -     -     -     -
   PSU2 Inlet Temp     
           not-available
                     - C      0     5    57    62
   PSU2 Hotspot Temp    
           not-available
                     - C      0     5    90    100
   PSU_FAN         
           not-available
   Module B Expander Temp 
              failed
                     - C      0     5    80    90
   Module A Expander Temp 
              failed
                     - C      0     5    80    90
   Midplane 4 Temp     failed
                     - C      0     5    55    60
   Midplane 3 Temp     failed
                     - C      0     5    55    60
   Midplane 2 Temp     failed
                     - C      0     5    55    60
   Midplane 1 Temp     failed
                     - C      0     5    55    60
   Ambient Temp      failed
                     - C      0     5    47    52