跳转到主内容

更换PSU后、SAS扩展器已将机箱LED设置为ON、即使重新启动BMC也是如此

Views:
19
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • FAS2720
  • 基板管理控制器(BMC)

问题描述

  • 更换PSU后、机箱警示LED保持亮起:

get_leds
========
FRU LEDs status
======================
FRU LED ID 1  = BMC Locate LED
FRU LED ID 2  = BMC System LED
FRU LED ID 3  = BMC Controller Attention LED
FRU LED ID 4  = BMC Controller Active LED
...
FRU LED ID 1 is off
FRU LED ID 2 is on. Set by Expander
FRU LED ID 3 is off
FRU LED ID 4 is on

  • 更换后PSU看起来正常:

/usr/local/bin/environ -show_all
================================
Sensor Name              State          Current    Critical     Warning     Warning    Critical
Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
PSU2 Bad                                 FALSE
PSU1 Bad                                 FALSE
PSU2                                      GOOD
PSU1                                      GOOD
PSU2 ON                                     ON
PSU1 ON                                     ON
PSU1 INFO                               FRU_AVAIL
PSU1 INFO                               FRU_AVAIL
PSU1 FRU                                  GOOD
PSU2 FRU                                  GOOD

  • 服务事件显示两个节点已设置机箱LED:

Node             ID  Event Location                      Event Description
---------------- --- ----------------------------------  ----------------------
Node-01           1   Chassis 1                           SAS Expander has set the Chassis LED ON
Node-02           1   Chassis 1                           SAS Expander has set the Chassis LED ON

  • 系统运行状况子系统未显示故障:

Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     ok
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster ok

  • 即使删除此服务事件后重新启动BMC或手动将LED设置为关闭状态、 问题描述仍会存在、并且此服务事件会再次引发。

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.