节点因SP HBT已停止警报而关闭

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009324381</a>
Last Updated:

适用场景

  • AFF-A300
  • FAS8200
  • 服务处理器 (SP)
  • ONTAP 9

问题描述

  • 节点发生故障、事件日志中出现以下错误:

[Node-02: spsm_listener: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 20 seconds.
[Node-02: spsm_listener: callhome.sp.hbt.missed:notice]: Call home for SP HBT MISSED
[Node-02: env_mgr: sp.ipmi.lost.shutdown:EMERGENCY]: SP heartbeat stopped and cannot be recovered. To prevent hardware damage and data loss, the system will shut down in 2 minutes.
[Node-02: spsm_listener: callhome.sp.hbt.stopped:alert]: Call home for SP HBT STOPPED

  • 即使重新启动并重新拔插、节点也无法启动。