跳转到主内容

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

将 RCF 文件应用于 Cisco Nexus 3132V-Q 集群交换机时出错

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • Cisco Nexus 3132V-Q 集群网络交换机
  • NX-OS 9.3.7
  • RCF1.6 (集群 HA 分支)

问题描述

将 RCF 应用于交换机时出现错误
 
`switch(config)# interface port-channel1`
`switch(config-if)# switchport mode trunk`
`switch(config-if)# spanning-tree port type network`
Warning: Bridge Assurance MUST be enabled at the remotely connected interface
`switch(config-if)# mtu 9216`
`switch(config-if)# no shutdown`
`switch(config-if)# class-map type qos match-all HA`
`switch(config-cmap-qos)# match cos 5 `
`switch(config-cmap-qos)# policy-map type qos HA `
`switch(config-pmap-qos)# class HA`
`switch(config-pmap-c-qos)# set qos-group 5`
`switch(config-pmap-c-qos)# class class-default`
`switch(config-pmap-c-qos)# set qos-group 0`
`switch(config-pmap-c-qos)# policy-map type queuing HA_EGRESS`
Invalid class referenced
% Invalid command at '^' marker.
`switch(config)# class type queuing c-out-8q-q6`
ERROR: Cannot modify system defined queuing class-maps

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device