跳转到主内容

控制台日志报告"panic:NVRAM in SLOT 6:unrec可 更正的内存错误at address"

Views:
55
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
HW
Last Updated:

适用场景

  • ONTAP 9
  • AFF A700、FAS9000 (插槽6中的NVRAM10模块)
  • AFF A900、ASA A900、FAS9500 (插槽6中的NVRAM11模块)

问题描述

  • 节点发生紧急情况、EMS中报告以下消息
  • ONTAP 9 .1中的示例:

[nvram.hw.fail:CRITICAL]: NVRAM hardware failed: Uncorrectable errors detected in NV-DIMM0. Replace NV-DIMM0.    
NV-DIMM fault LED has been turned on.

[nvram.hw.fail:CRITICAL]: NVRAM hardware failed: Uncorrectable errors detected in NV-DIMM1. Replace NV-DIMM1.    
NV-DIMM fault LED has been turned on.

PANIC: NVRAM in slot 6: uncorrectable memory error at address 0x2dd33fe00 DIMM(0), Rank(0), Bank Group(0),
Bank(0x2), Row(0x16e99), Col(0x3f8) in process idle on release 9.1P11 (C) on Fri Mar 20 04:03:31 UTC 2020      
version: 9.1P11: Thu Dec 21 02:32:26 PST 2017
compile flags: x86_64.optimize
HA: current time (in sk_msecs) 15241160060 (in sk_cycles) 58865735105269550

  • ONTAP 9.3 及更高版本的示例:

Tue Jan 11 06:40:51 GMT [nvram.hw.fail:CRITICAL]: NVRAM hardware failed: Uncorrectable errors detected in NV-DIMM2.
Replace NV-DIMM2. NV-DIMM fault LED has been turned on.

PANIC: NVRAM in slot 6: uncorrectable memory error at address 0x1011de688 DIMM(1), Rank(0), Bank Group(2),
Bank(0x0), Row(0x1011d), Col(0x399) in process idle: cpu7 on release 9.7P16 (C) on Tue Jan 11 01:40:51 EST 2022   
version: 9.7P16: Fri Sep 10 18:35:49 EDT 2021

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.