问题
在"适用"部分的平台中添加扩展卡时,卡片可能不会显示在"sysconfig -ac"中。 控制台和 EMS 日志中也会出现类似以下错误:
Jun 03 19:42:40 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS Power Good Power Fault.
Jun 03 19:42:40 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS Hot Swap Cur is critical low (0 mA).
Jun 03 19:42:40 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS Power Good Power Fault.
Jun 03 19:42:40 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS Hot Swap Cur is critical low (0 mA).
Jun 03 19:42:50 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS P3.3V is not readable
Jun 03 19:42:50 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS P1.8V is not readable
Jun 03 19:42:50 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS P1.0V is not readable
Jun 03 19:42:50 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS P0.9V is not readable
Jun 03 19:42:50 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO11 SAS 5V Standby is not readable
Jun 03 19:43:11 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS P3.3V is not readable
Jun 03 19:43:12 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS P1.8V is not readable
Jun 03 19:43:12 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS P1.0V is not readable
Jun 03 19:43:12 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS P0.9V is not readable
Jun 03 19:43:12 [Cluster-01:monitor.ioCard.degraded:ALERT]: IO card is degraded: IO3 SAS 5V Standby is not readable