跳转到主内容

使用第三方存储的FlexArray 中出现多磁盘崩溃

Views:
21
Visibility:
Public
Votes:
0
Category:
v-series-flexarray
Specialty:
san
Last Updated:

适用场景

  • ONTAP 9
  • FlexArray 设置
  • 第三方存储

问题描述

  • 在FlexArray配置中、所有可用路径上缺少一个或多个LUN将导致多磁盘出现崩溃。
  • FlexArray聚合在RAID 0中配置
  • Flex阵列不支持第三方存储的RAID冗余(RAID 4、raidDP、raidTEC)
  • 如果无法从HA配对节点访问第三方存储、则HA配对节点将无法接管

Panic string: aggr aggrname: raid volfsm, fatal disk error in RAID group with no parity disk. raid type raid0 in SK process config_thread on release 9.x (C)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.