适用场景

  • ONTAP 9
  • FAS8300
  • FCP
  • LogicMonitor

问题描述

  • 监控软件报告单个FCP适配器loss_of_sync间歇性 :
NetApp Fibre Channel Adapter node2/2c on cluster1 has reported a synchronization loss, placing the adapter into warn state.
This adapter has lost synchronization a total of 1565.0 times. This is commonly caused by link failures.
  • 适配器处于联机状态
  • 电源电平正常
  • EMS无错误
  • 连接的Brocade交换机在porterrshow 中未显示错误、并且电源级别正常
  • 已清理SFP和缆线
  • 已更换电缆
  • 可以在fcp_port 对象的loss_of_sync 计数器上看到问题描述:
time interval             fcp_port    fcp_port
                    instance  loss_of_sync
 
------------------------------------  --------  ------------
2025-02-06 19:16:43 - 19:21:43+01:00  port.2c        1
2025-02-06 20:16:43 - 20:21:43+01:00  port.2c        1
2025-02-06 21:16:43 - 21:21:43+01:00  port.2c        1
2025-02-06 23:21:43 - 23:26:43+01:00  port.2c        1
2025-02-07 01:41:43 - 01:46:43+01:00  port.2c        1
2025-02-07 02:21:43 - 02:26:43+01:00  port.2c        1
2025-02-07 04:01:43 - 04:06:43+01:00  port.2c        1

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.