适用场景

  • VMware ESXi 6.X
  • VMware ESXi 7.X
  • Brocade 交换机上的端口

问题描述

  • VMware ESXi 主机 HBA 端口显示增量为 Invalid CRC Count 和 Invalid TX Word Count 。
Adapter: vmhba1
Tx Frames: 2929696924
Rx Frames: 3782738436
Lip Count: 0
Error Frames: 0
Dumped Frames: 0
Link Failure Count: 21
Loss of Signal Count: 1
PrimSeq Protocol Err Count: 0
Invalid Tx Word Count: 524313192
Invalid CRC Count: 294694
Input Requests: 305122439
Output Requests: 299737927
Control Requests: 0
Tue Jan 25 06:42:07 UTC 2022
 
 
  • Brocade 显示 c3timeouts

   frames    enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs
   tx    rx   in   err   g_eof  shrt   long   eof    out   c3   fail   sync   sig          tx   rx   err
20: 1.3g 397.0m   0    0    0    0    0    0    0   5.9k   0    0    0    0    0   5.9k  0    0