跳转到主内容

由于交换机端SFP出现故障、VMware路径失败和FCP命令失败

Views:
31
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

适用场景

  • VMware
  • FCP
  • ONTAP
  • Brocade 交换机上的端口

问题描述

  • VMware存储路径闪烁、生成警报、

Alarm 'Cannot connect to storage' on xxx.xx.x.xx triggered by event 49104432 'Path redundancy to storage device naa.600a09803831460000000000000000 degraded. Path vmhba1:XX:XX:Xxx is down. Affected datastores: XX_NETAPP_SANxx.'

  • 存储适配器端口登录连接到VMware、并在EMS中记录以下链路中断错误、

[?]  Sat Mar 23 02:16:10 +0000 [CLUSTER1-01: fct_tpd_work_thread_0: scsitarget.slifct.linkBreak:error]: Link break detected on Fibre Channel target HBA 2a with event status 1 , topology type 1, status1 0x0, status2 0x0.
[?]  Sat Mar 23 02:16:11 +0000 [CLUSTER1-01: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 2a.
[?]  Sat Mar 23 02:16:13 +0000 [CLUSTER1-01: fct_tpd_work_thread_0: scsitarget.fct.portLogin:notice]: Login at target FC port: '2a' by initiator port: '10:00:00:62:xx:xx:xx:xx address 0x00000. The target virtual port is: 'NetApp FC Target Port (LPe00000) SVM:n1_fc_2a'.

  • 对于 适配器端口(主端口)的LIF、ONTAP系统管理器出现LIF操作关闭错误。
  • errdump -a 在连接到存储适配器端口的交换机端口上存在"帧超时"事件。

2024/03/20-02:40:17, [AN-1014], 2665374, FID 128, INFO, SBI-LIFE-G620-R4U27-SANSW1, Frame timeout detected, tx port 16 rx port 19, sid 11315, did 11001, timestamp 2024-03-20 02:40:17 .

  • portershow具有高 磁盘C3、链路故障丢失同步错误、

porterrshow     :
      frames    enc   crc   crc   too   too   bad   enc   disc   link   loss   loss   frjt   fbsy  c3timeout   pcs   uncor
    tx    rx    in   err   g_eof  shrt   long   eof    out   c3   fail   sync   sig          tx   rx    err   err
16:   3.1g   2.1g   0   151    17    7    0   135    0    1.8m   2.4m   4.8m 644    0    0    1.8m   0    28.7k  32.3k

=============
Port 16:
=============
RX Power:   -2.1   dBm (613.4uW)
TX Power:   -0.4   dBm (914.7 uW)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.