跳转到主内容

由于缆线松动/出现故障、Brocade FC端口脱机并处于No_Sync状态

Views:
15
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009452218</a>
Specialty:
san
Last Updated:

适用场景

  • Brocade FC 交换机
  • 网络结构操作系统( FOS )

问题描述

  • Brocade光纤通道端口处于、No_syncDisabledswitchshow输出下处于状态: 

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed        State    Proto
============================================================

228 11 20 6be400 id N32 No_Sync FC Disabled (Port Throttled)

 

  • Portershow报告链路故障和los_sync错误。

/fabos/cliexec/porterrshow :
      frames     enc    crc    crc    too    too    bad    enc   disc   link  loss  loss   frjt   fbsy    c3timeout    pcs    uncor
     tx     rx    in    err    g_eof   shrt   long   eof    out   c3    fail  sync  sig            tx    rx    err    err
228:   10.5g   16.2g    0       0       0       0       0       0       0       0      14     15      0       0       0       0       0       0       0

 

  • sfpshow报告Rx功率低:

=============
Slot  4/Port  24:
=============

RX Power:   -20.2   dBm (9.6  uW)
TX Power:   -0.6   dBm (879.9 uW)

 

  • Fabriclog输出报告的链路故障:
Switch 0; Sun Jan 29 12:04:25 2023 IST (GMT+5:30) 12:04:25.839042 SCN Port Offline;rsn=0x3,g=0xc44 D2,P0 D2,P0 228 NA 12:04:25.839049 *Removing all nodes from port D2,P0 D2,P0 228 NA 22:21:42.632387 SCN LR_PORT(0);g=0xc44 D2,P0 D2,P0 228 NA 22:21:42.666236 SCN Port Online; g=0xc44,isolated=0 D2,P0 D2,P1 228 NA 22:21:42.666376 Port Elp engaged D2,P1 D2,P0 228 NA 22:21:42.666389 *Removing all nodes from port D2,P0 D2,P0 228 NA 22:21:42.666643 SCN Port F_PORT D2,P1 D2,P0 228 NA 22:27:49.180108 SCN Port Offline;rsn=0x10004,g=0xc46 D2,P0 D2,P0 228 NA 22:27:49.180115 *Removing all nodes from port D2,P0 D2,P0 228 NA 22:29:29.082525 SCN LR_PORT(0);g=0xc46 D2,P0 D2,P0 228 NA 22:29:29.114287 SCN Port Online; g=0xc46,isolated=0 D2,P0 D2,P1 228 NA 22:29:29.114347 Port Elp engaged D2,P1 D2,P0 228 NA 22:29:29.114358 *Removing all nodes from port D2,P0 D2,P0 228 NA 22:29:29.114583 SCN Port F_PORT D2,P1 D2,P0 228 NA
  • 验证交换机端SFP Tx和Rx电源是否在建议的范围内。

  • 低Rx电源表示交换机上游的问题描述 、硬件出现故障、包括缆线和终端设备SFP。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.