由于终端设备SFP出现故障、Brocade FC端口脱机并处于No_Sync状态
适用场景
- Brocade FC 交换机
- 光纤操作系统(FOS)
问题描述
- Brocade光纤通道端口处于
No_syncDisabledswitchshow输出下的状态:
/fabos/bin/switchshow :
Index Slot Port Address Media Speed State Proto
============================================================
120 4 24 6f7800 id N32 No_Sync FC Disabled (Port Throttled)
152 4 24 0f9840 id N32 No_Sync FC Disabled (Port State Change threshold exceeded)
PCS error,uncorr error以及link failloss signal errors在下报告的porterrshow
porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
152: 22.6k 15.2k 0 0 0 0 0 0 0 0 16 17 17 0 0 0 0 4.1k 1.1k
defALL_HOST_PORTSITW_21在受影响交换机端口上通过errdump以下命令报告的规则:
2023/01/06-01:18:52, [MAPS-1003], 207782, SLOT 2 | FID 128, WARNING, switch, slot12 port37, F-Port 12/37, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 5616 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
2023/01/06-16:45:46, [MAPS-1003], 208332, SLOT 2 | FID 128, WARNING, switch, slot12 port37, F-Port 12/37, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 1764 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
sfpshow报告建议范围内的Tx和Rx功率
=============
Slot 4/Port 24:
=============
RX Power: -0.6 dBm (861.3uW)
TX Power: -0.3 dBm (933.0 uW)
- 由于端口处于
Disabled状态、sfpshow输出报告Tx功率非常低、Rx功率接近阈值。
Slot 4/Port 24:
=============
RX Power: -3.5 dBm (451.1uW)
TX Power: -40.0 dBm (0.1 uW)
sfpshow将低Rx和Tx功率报告为-inf:
=============
Slot 12/Port 37:
=============
RX Power: -8.8 dBm (132.0uW)
TX Power: -inf dBm (0.0 uW)
Porterrshow不会报告交换机端口上的任何错误。
/fabos/cliexec/porterrshow:
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
238: 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
sfpshow报告建议范围内的Tx功率、但 报告的Rx功率较低。
RX Power: -9.9 dBm (102.6uW)
TX Power: -0.8 dBm (837.1 uW)
- 多个
link resets报告依据errdump:
2022/11/11-18:22:58, [C5-1014], 17914, SLOT 1 | CHASSIS, WARNING, XXX, Link Reset on Port S6,P296(120) vc_no=3 crd(s)lost=1 auto trigger.
2022/11/11-18:29:41, [C5-1040], 17915, SLOT 1 | CHASSIS, WARNING, XXX, Multi RDY/Frame Loss detected on Slot 6, Port 296(120) m_rdy(0x0)/m_frame(0x1). Link Reset done.
2022/11/11-18:29:41, [C5-1014], 17916, SLOT 1 | CHASSIS, WARNING, XXX, Link Reset on Port S6,P296(120) vc_no=0 crd(s)lost=1 auto trigger.
2022/11/11-18:39:24, [C5-1023], 17918, SLOT 1 | CHASSIS, WARNING, XXX, Single RDY/Frame Loss detected and recovered on Slot 6,Port 296(120) rdy(0x0)/frame(0x1).
2022/11/11-18:43:46, [C5-1040], 17919, SLOT 1 | CHASSIS, WARNING, XXX, Multi RDY/Frame Loss detected on Slot 6, Port 296(120) m_rdy(0x0)/m_frame(0x1). Link Reset done.
2022/11/11-18:43:46, [C5-1014], 17920, SLOT 1 | CHASSIS, WARNING, XXX, Link Reset on Port S6,P296(120) vc_no=0 crd(s)lost=1 auto trigger.
- 连接到Brocade交换机的NetApp端口的状态显示为
Link Disconnected""
slot 0: Fibre Channel Target Host Adapter 0e
(QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
Firmware rev: 8.9.0
Flash rev: 5.0.2
Host Port Addr: 000000
- 连接到交换机端口的NetApp端口 显示Rx和Tx:0.0 (uWatt)
- Brocade交换机端口报告""
No_Light状态。
Index Slot Port Address Media Speed State Proto
============================================================
202 9 26 01ca00 id N32 No_Light FC
portshow交换机上的输出报告portstate为Offline""。
portshow 202
portDisableReason: None
portCFlags: 0x1
portFlags: 0x41PRESENT
LocalSwcFlags: 0x0
portType: 26.0
portState: Offline
Protocol: FC
portPhys: No_Light