跳转到主内容

由于终端设备SFP出现故障、Brocade FC端口脱机并处于No_Sync状态

Views:
359
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches<a>2009412512</a>
Specialty:
san
Last Updated:

适用场景

  • Brocade FC 交换机
  • 光纤操作系统(FOS)

问题描述

  • Brocade光纤通道端口处于 No_sync  Disabledswitchshow 输出下的状态: 

/fabos/bin/switchshow :
Index Slot Port Address Media  Speed        State    Proto
============================================================
120 4 24 6f7800 id N32 No_Sync FC Disabled (Port Throttled)

 152   4   24   0f9840   id   N32    No_Sync    FC  Disabled (Port State Change threshold exceeded)
 

 

  • PCS error , uncorr error 以及 link fail loss signal errors 在下报告的 porterrshow

porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
152: 22.6k 15.2k 0 0 0 0 0 0 0 0 16 17 17 0 0 0 0 4.1k 1.1k

 

  • defALL_HOST_PORTSITW_21 在受影响交换机端口上通过 errdump以下命令报告的规则:

2023/01/06-01:18:52, [MAPS-1003], 207782, SLOT 2 | FID 128, WARNING, switch, slot12 port37, F-Port 12/37, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 5616 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.
2023/01/06-16:45:46, [MAPS-1003], 208332, SLOT 2 | FID 128, WARNING, switch, slot12 port37, F-Port 12/37, Condition=ALL_HOST_PORTS(ITW/min>21), Current Value:[ITW, 1764 ITWs], RuleName=defALL_HOST_PORTSITW_21, Dashboard Category=Port Health.

 

  • sfpshow 报告建议范围内的Tx和Rx功率

=============
Slot  4/Port  24:
=============

RX Power:   -0.6   dBm (861.3uW)
TX Power:   -0.3   dBm (933.0 uW)

  • 由于端口处于 Disabled 状态、 sfpshow 输出报告Tx功率非常低、Rx功率接近阈值。

Slot  4/Port 24:
=============
RX Power:   -3.5   dBm (451.1uW)
TX Power:   -40.0   dBm (0.1   uW)

  • sfpshow 将低Rx和Tx功率报告为 -inf:

=============
Slot 12/Port 37:
=============
RX Power: -8.8 dBm (132.0uW)
TX Power: -inf dBm (0.0 uW)

 

  • Porterrshow 不会报告交换机端口上的任何错误。

/fabos/cliexec/porterrshow:
      frames     enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy    c3timeout    pcs    uncor
     tx     rx    in    err    g_eof   shrt   long   eof    out   c3    fail   sync   sig            tx    rx    err    err
238:   0     0     0     0     0     0     0     0     0     0     0     0     0     0     0     0     0     0     0

 

  • sfpshow 报告建议范围内的Tx功率、但 报告的Rx功率较低。

RX Power: -9.9 dBm (102.6uW)
TX Power: -0.8 dBm (837.1 uW)

 

  • 多个 link resets 报告依据 errdump

2022/11/11-18:22:58, [C5-1014], 17914, SLOT 1 | CHASSIS, WARNING, XXX,  Link Reset on Port S6,P296(120) vc_no=3 crd(s)lost=1 auto trigger.
2022/11/11-18:29:41, [C5-1040], 17915, SLOT 1 | CHASSIS, WARNING, XXX, Multi RDY/Frame Loss detected on Slot 6, Port 296(120) m_rdy(0x0)/m_frame(0x1). Link Reset done.
2022/11/11-18:29:41, [C5-1014], 17916, SLOT 1 | CHASSIS, WARNING, XXX,  Link Reset on Port S6,P296(120) vc_no=0 crd(s)lost=1 auto trigger.
2022/11/11-18:39:24, [C5-1023], 17918, SLOT 1 | CHASSIS, WARNING, XXX, Single RDY/Frame Loss detected and recovered on Slot 6,Port 296(120) rdy(0x0)/frame(0x1).
2022/11/11-18:43:46, [C5-1040], 17919, SLOT 1 | CHASSIS, WARNING, XXX, Multi RDY/Frame Loss detected on Slot 6, Port 296(120) m_rdy(0x0)/m_frame(0x1). Link Reset done.
2022/11/11-18:43:46, [C5-1014], 17920, SLOT 1 | CHASSIS, WARNING, XXX,  Link Reset on Port S6,P296(120) vc_no=0 crd(s)lost=1 auto trigger.

 

  • 连接到Brocade交换机的NetApp端口的状态显示为Link Disconnected""

 slot 0: Fibre Channel Target Host Adapter 0e
        (QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
         Firmware rev:    8.9.0
         Flash rev:      5.0.2
         Host Port Addr:   000000

  • 连接到交换机端口的NetApp端口 显示Rx和Tx:0.0 (uWatt)

 

  • Brocade交换机端口报告""No_Light状态。

Index Slot Port Address Media  Speed     State   Proto
============================================================
 202   9   26  01ca00  id   N32 No_Light  FC

  • portshow 交换机上的输出报告 portstateOffline""。

portshow 202
portDisableReason: None
portCFlags: 0x1
portFlags: 0x41PRESENT
LocalSwcFlags: 0x0
portType:  26.0
portState: Offline
Protocol: FC
portPhys:  No_Light

 

  • 以下是应遵循的一些故障排除步骤:

    • `验证交换机端SFP Tx和Rx电源是否在 建议 范围内

    • 要进行故障隔离,请交换交换机端SFP并执行 电缆测试

    • 如果问题仍然存在、 则必须检查终端设备。  更换交换机端SFP并测试缆线后、联系主机供应商寻求帮助。

    • 检查HHBA/host并确认HBA能够运行的速度、然后尝试 使用 portCfgSpeed 命令和check相应地(手动)设置交换机端口的速度。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.