NetApp_Insight_2020.png 

Brocade 交换机显示警告:端口上的链路重置

Views:
10
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用于

Brocade 交换机上的端口

问题

  • Brocade 交换机将显示  Link Reset on Port

2020/04/08-21:35:56, [C3-1014], 2556, CHASSIS, WARNING, Brocade6510,  Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger.
2020/04/09-09:03:42, [C3-1014], 2557, CHASSIS, WARNING, Brocade6510,  Link Reset on Port S0,P8(12) vc_no=0 crd(s)lost=12 auto trigger. 

  • 在命令上、 RX 的 Brocade TX 电源低于 300 UW sfpshow -all

=============
Port  8:
=============
Identifier:  3   SFP
Connector:   7   LC
Transceiver: 7004404000000000 4,8,16_Gbps M5 sw Short_dist
Encoding:   6   64B66B 
Baud Rate:   140  (units 100 megabaud)
Length 9u:   0   (units km)
Length 9u:   0   (units 100 meters)
Length 50u (OM2):  3   (units 10 meters)
Length 50u (OM3):  10   (units 10 meters)
Length 62.5u:0   (units 10 meters)
Length Cu:   0   (units 1 meter)
Vendor Name: BROCADE      
Vendor OUI:  00:05:1e
Vendor PN:   57-0000088-01   
Vendor Rev:  A   
Wavelength:  850  (units nm)
Options:    003a Loss_of_Sig,Tx_Fault,Tx_Disable
BR Max:    0   
BR Min:    0   
Serial No:   HAF6182300004BC 
Date Code:   180605  
DD Type:    0x68
Enh Options: 0xfa
Status/Ctrl: 0x0
Pwr On Time: 1.24 years (10834 hours)
E-Wrap Control: 0
O-Wrap Control: 0
Alarm flags[0,1] = 0x5, 0x40
Warn Flags[0,1] = 0x5, 0x40
Temperature: 55    Centigrade 
Current:    7.506   mAmps 
Voltage:    3314.0  mVolts 
RX Power:   -2.8   dBm (520.8uW) 
TX Power:   -10.3  dBm (92.4  uW) 

 